Skip to main content

Website overview


Radiation dose converters

Dose unit converter


Information on quantities and website


Miscellaneous calculators




Comments

  1. I've been looking for info on this topic for a while. I'm happy this one is so great. Keep up the excellent work jasa bikin website

    ReplyDelete
  2. this one is so great. Keep up the excellent work nama free fire keren

    ReplyDelete
  3. I am searching all these tools from last two days. I am happy to see all these important tools at a same place. These tools solves various complex queries in just few seconds. That's why i love the technology, and always ready to learn new technologies.

    ReplyDelete

Post a Comment

Popular posts from this blog

DAP unit converter

With this converter, the dose area product (DAP) can be converted into corresponding values expressed by other units. Use other tool for DAP to effective dose (mSv) conversion. Note: use point in stead of comma as a decimal separator. DAP unit converter Type a value in the DAP field to convert to DAP in other units: DAP From mGy.cm2 cGy.cm2 dGy.cm2 Gy.cm2 uGy.m2 mGy.m2 Gy.m2 To mGy.cm2 cGy.cm2 dGy.cm2 Gy.cm2 uGy.m2 Gy.m2   Result DAP Simple example with respect to unit conversions: When converting from Gy.cm2 to µGy.m2 the following reasoning can be followed: 1 Gy = 1,000,000 (1 million) µGy; 1 cm2 = 0.0001 m2; this means that 1 Gy.cm2 = 1,000,000*0.0001 µGy.m2 = 100 µGy.m2. Note that some con

DAP to mSv converter - radiography

This tool calculates the effective dose (mSv) with respect to the DAP value (e.g. cGy.cm2) belonging to different types of radiograph . It does for instance, Gy.cm2 to mSv conversion. It is emphasized that the result is an estimation. The conversion factor relates to ICRP 103 and is obtained from: Radiation risks from medical x-ray examinations as a function of the age and sex of the patient, BF Wall et al., Report HPA-CRCE-028 (2011) ; www.hpa.org.uk Note: use point in stead of comma as a decimal separator. Input value dose area product (DAP) Gy.cm2 mGy.cm2 cGy.cm2 dGy.cm2 Gy.m2

Dose area product (DAP)

Dose Area Product (DAP), is a multiplication of the dose and the area exposed, often expressed in Gy.cm2.  Modern x-ray systems are fitted with a DAP meter, able to record accumulated DAP during an  examination. A schematic of the imaging chain with DAP meter is given below. How is DAP measured? An ionization chamber larger than the area of the x-ray beam is placed just beyond the xray collimators. The DAP ionization chamber must intercept the entire x-ray field for an accurate reading. The DAP-value is depending on x-ray technique factors (kVp, mA, filtration) and time of the procedure and the area of the x-ray field. For example, a 5 x 5 cm x-ray field with an entrance dose of 1 mGy will yield a 25 mGy.cm2 DAP value. If the field is increased to 10 x 10 cm, with the same entrance dose of 1 mGy the DAP increases to 100 mGy-cm2, which is 4 times the DAP for the 5 x 5 cm field. Why DAP? Dose-area product is relatively easy to measure. DAP has been shown to correlate well with the

Radiation dose converters

Radiation dose converters DAP unit converter DAP to mSv converter DLP unit converter Effective dose calculator - DLP Dose rate converter

DLP unit converter

With this converter, the dose length product (DLP) can be converted into corresponding values expressed by other units. Note: use point in stead of comma as a decimal separator. Input value   from     mGy.cm cGy.cm dGy.cm Gy.cm uGy.m mGy.m cGy.m dGy.m Gy.m to     mGy.cm cGy.cm dGy.cm Gy.cm uGy.m mGy.m cGy.m dGy.m Gy.m

Effective dose calculator - CTA-chest

This converter converts DLP in mSv effective dose.  Note 1: use point in stead of comma as a decimal separator.  Note 2: currently only for CTA-chest and a rough estimate. Input value (DLP) mGy.cm cGy.cm dGy.cm Gy.cm Gy.m Result Effective dose mSv

Dose rate converter

Dose rate is defined as: the quotient of the dose over a given period of time, and this duration. For example, the dose rate can be expressed in units of Gy/h. This converter helps to convert dose rate into another unit. Input value   from  uGy/s uGy/m uGy/h mGy/s mGy/m mGy/h cGy/s > to  uGy/s uGy/m uGy/h mGy/s mGy/m mGy/h cGy/h >                                     ...or use SHARE button f

DAP in DICOM header

DAP value in DICOM headers is given in dGy*cm*cm. It can be found at DICOM Tag (0018,115E). For more detail, see for instance this  web page .

Dose Unit Conversion Tool

For radiation units and conversion factors the following link from REMM - US Department of Health and Human Services - is useful: Dose unit conversion tool